See more

    CONTEC CA10M VET ETCO2 Capnograph Respiration Rate Monitor For Animals

    915569c2-d044-46e9-8cd8-c2fee48875e9

    $259.99
    915569c2-d044-46e9-8cd8-c2fee48875e9

    Data sheet

    Specific References

    Introduction

    The device adopts mainstream method to measure end-tidal carbon dioxide(EtCO2) and airway respiratory rate(AwRR). It can monitor the pet’s ventilation function, reflect the condition of pulmonary circulation and pulmonary blood flow, and indirectly reflect the alveolar ventilation. It has important application value in clinical anesthesia, cardiopulmonary cerebral resuscitation, prehospital emergency care, ICU and post-anesthesia of pets. It connects with the pet’s respiratory tract through the air adapter and respiratory connection tube.


    Features

    1)End-tidal CO2 measurement function;
    2)Respiration rate measurement function;
    3)Optional three units;
    4)With audible and visual alarm and silencing functions, the alarm limit can be set;
    5)Over-limit alarm function for End-tidal CO2 and respiration rate;
    6)Low battery alarm function;
    7)With the prompt function of “Adapter off”;
    8)Users can calibrate zero by themselves.
    9)With atmospheric pressure and temperature compensation functions;
    10)Waterproof and dustproof grade grade:IP22;
    11)Degree of protection against electric shock: type BF applied part
    12)Install 2 AAA dry batteries, up to 4-hour user time.
    13)It can be used in highland enviroments.


    Performance

    End-tidal CO2 measurement:
    1)Measurement range: 0 ~150mmHg
    2)Resolution: 1mmHg
    3)Accuracy:
    0~40 mmHg:±2 mmHg
    41~70 mmHg:±5% of readings
    71~100 mmHg:±8% of readings
    101~150 mmHg:±10% of readings
    Respiration rate measurement:
    1)Measurement range: 2rpm~150rpm
    2)Resolution: 1rpm
    3)Accuracy: ±1rpm
    Safety characteristic:
    1)Device type: internally powered equipment
    2)Degree of protection against electric shock: type BF applied part
    3)Protection grade: IP22
    Other parameters:
    1)Preheat time:15s
    2)Response time:< 3s
    3)Alarm sound pressure level: 50 dB
    4)Battery life time:4hours


    Accessories

    ★ A User Manual
    ★ An air adapter
    ★ 2 AAA dry batteries


    Physical Characteristic

    Dimension: 59×56×59.5mm
    Weight: 92g (with batteries)
    Working environment
    Temperature: 5℃~40℃
    Relative humidity: 30%~ 75%, no condensation
    Atmospheric pressure: 700hPa~1060hPa
    Power supply: DC 3V (2 AAA dry batteries)
    Input power: ≤1VA